Skip to main content

Intracranial dual-mode IVUS transducer for image-guided brain therapypreliminary experiments

Publication ,  Journal Article
Herickhoff, CD; Wolf, PD; Smith, SW; Grant, GA; Britz, GW; Wilson, CM
Published in: Proceedings - IEEE Ultrasonics Symposium
December 1, 2010

In this study, we investigated the feasibility of using 3.5-Fr IVUScatheters for minimally-invasive, image-guided hyperthermia treatment of tumorsin the brain. Feasibility is demonstrated in two ways: 1) by fitting a 3.5-FrIVUS catheter with a 5 × 0.5 × 0.22 mm PZT-4 transducer for 9-MHzimaging, and 2) by testing an identical transducer for therapy potential with3.3-MHz CW excitation. The imaging transducer's performance was compared to a9-Fr, 9-MHz ICE catheter as a gold standard, visualizing a 2.5-cm cyst phantomand a postmortem ovine brain. The therapy transducer was able to maintain apower output of 700 mW, achieving a temperature rise of 19°C at a depth of1.5 mm in excised brain tumor tissue. © 2010 IEEE.

Duke Scholars

Published In

Proceedings - IEEE Ultrasonics Symposium

DOI

ISSN

1051-0117

Publication Date

December 1, 2010

Start / End Page

1502 / 1505
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Herickhoff, C. D., Wolf, P. D., Smith, S. W., Grant, G. A., Britz, G. W., & Wilson, C. M. (2010). Intracranial dual-mode IVUS transducer for image-guided brain therapypreliminary experiments. Proceedings - IEEE Ultrasonics Symposium, 1502–1505. https://doi.org/10.1109/ULTSYM.2010.5935594
Herickhoff, C. D., P. D. Wolf, S. W. Smith, G. A. Grant, G. W. Britz, and C. M. Wilson. “Intracranial dual-mode IVUS transducer for image-guided brain therapypreliminary experiments.” Proceedings - IEEE Ultrasonics Symposium, December 1, 2010, 1502–5. https://doi.org/10.1109/ULTSYM.2010.5935594.
Herickhoff CD, Wolf PD, Smith SW, Grant GA, Britz GW, Wilson CM. Intracranial dual-mode IVUS transducer for image-guided brain therapypreliminary experiments. Proceedings - IEEE Ultrasonics Symposium. 2010 Dec 1;1502–5.
Herickhoff, C. D., et al. “Intracranial dual-mode IVUS transducer for image-guided brain therapypreliminary experiments.” Proceedings - IEEE Ultrasonics Symposium, Dec. 2010, pp. 1502–05. Scopus, doi:10.1109/ULTSYM.2010.5935594.
Herickhoff CD, Wolf PD, Smith SW, Grant GA, Britz GW, Wilson CM. Intracranial dual-mode IVUS transducer for image-guided brain therapypreliminary experiments. Proceedings - IEEE Ultrasonics Symposium. 2010 Dec 1;1502–1505.

Published In

Proceedings - IEEE Ultrasonics Symposium

DOI

ISSN

1051-0117

Publication Date

December 1, 2010

Start / End Page

1502 / 1505