Skip to main content
Journal cover image

Double Ring Array Catheter for In Vivo Real-Time 3D Ultrasound.

Publication ,  Journal Article
Smith, SW; Gardea, P; Patel, V; Douglas, SJ; Wolf, PD
Published in: Ultrasonic imaging
July 2014

We developed new forward-viewing matrix transducers consisting of double ring arrays of 118 total PZT elements integrated into catheters used to deploy medical interventional devices. Our goal is 3D ultrasound guidance of medical device implantation to reduce x-ray fluoroscopy exposure. The double ring arrays were fabricated on inner and outer custom polyimide flexible circuits with inter-element spacing of 0.20 mm and then wrapped around an 11 French (Fr) catheter to produce a 15 Fr catheter (outer diameter [O.D.]). We used a braided cabling technology to connect the elements to the Volumetrics Medical Imaging (VMI) real-time 3D ultrasound scanner. Transducer performance yielded an average -6 dB fractional bandwidth of 49% ± 11% centered at 4.4 MHz for 118 elements. Real-time 3D cardiac scans of the in vivo pig model yielded good image quality including en face views of the tricuspid valve and real-time 3D guidance of an endo-myocardial biopsy catheter introduced into the left ventricle.

Duke Scholars

Published In

Ultrasonic imaging

DOI

EISSN

1096-0910

ISSN

0161-7346

Publication Date

July 2014

Volume

36

Issue

3

Start / End Page

167 / 176

Related Subject Headings

  • Acoustics
  • 4003 Biomedical engineering
  • 0903 Biomedical Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Smith, S. W., Gardea, P., Patel, V., Douglas, S. J., & Wolf, P. D. (2014). Double Ring Array Catheter for In Vivo Real-Time 3D Ultrasound. Ultrasonic Imaging, 36(3), 167–176. https://doi.org/10.1177/0161734614523738
Smith, Stephen W., Paul Gardea, Vivek Patel, Stephen J. Douglas, and Patrick D. Wolf. “Double Ring Array Catheter for In Vivo Real-Time 3D Ultrasound.Ultrasonic Imaging 36, no. 3 (July 2014): 167–76. https://doi.org/10.1177/0161734614523738.
Smith SW, Gardea P, Patel V, Douglas SJ, Wolf PD. Double Ring Array Catheter for In Vivo Real-Time 3D Ultrasound. Ultrasonic imaging. 2014 Jul;36(3):167–76.
Smith, Stephen W., et al. “Double Ring Array Catheter for In Vivo Real-Time 3D Ultrasound.Ultrasonic Imaging, vol. 36, no. 3, July 2014, pp. 167–76. Epmc, doi:10.1177/0161734614523738.
Smith SW, Gardea P, Patel V, Douglas SJ, Wolf PD. Double Ring Array Catheter for In Vivo Real-Time 3D Ultrasound. Ultrasonic imaging. 2014 Jul;36(3):167–176.
Journal cover image

Published In

Ultrasonic imaging

DOI

EISSN

1096-0910

ISSN

0161-7346

Publication Date

July 2014

Volume

36

Issue

3

Start / End Page

167 / 176

Related Subject Headings

  • Acoustics
  • 4003 Biomedical engineering
  • 0903 Biomedical Engineering