A Comparative Study of Rebound Tonometry With Tonopen and Goldmann Applanation Tonometry Following Vitreoretinal Surgery.
PURPOSE: To investigate agreement in intraocular pressure (IOP) measurements among Icare rebound tonometry, Tonopen tonometry, and Goldmann applanation tonometry following vitreoretinal surgery. DESIGN: Reliability analysis of tonometers. METHODS: Fifty-eyes of 50 adults undergoing vitreoretinal surgery were enrolled. IOP was measured on first postoperative day using Icare (Tiolat, Helsinki, Finland), followed by Tonopen (Reichert, Depew, New York, USA) and Goldmann (Haag-Streit USA, Mason, Ohio, USA) in randomized order. Intraclass correlation coefficients (ICC) and Bland-Altman plots were calculated for all subcategories. RESULTS: Icare successfully measured IOP in all eyes, while Goldmann was unmeasurable in 6 eyes (12%) and Tonopen in 1 eye (2%). Mean IOP by Icare, Tonopen, and Goldmann was 15.9 ± 8.9, 16.9 ± 6.2, and 16.0 ± 7.3 mm Hg, respectively (P = .76). Type of intraocular tamponade, status of lens, status of cornea, gauge of instrumentation, and history of prior vitrectomy did not result in significant differences among the 3 tonometers. ICC was excellent (>0.75) in all subgroups, except at IOP <10 and ≥ 23 mm Hg (based on Icare). In eyes with IOP <10 mm Hg, Icare underestimated IOP (mm Hg; P = .01) compared to Goldmann (2.0 ± 2.1) and Tonopen (3.5 ± 2.4), whereas at IOP ≥ 23 mm Hg Icare was overestimated (P = .01) compared to Goldmann (3.77 ± 3.49) and Tonopen (4.97 ± 3.33). Overall, differences in IOP were ≤ 3 mm Hg in 58% of eyes for Icare-Tonopen, 72% for Tonopen-Goldmann, and 62% for Icare-Goldmann. CONCLUSION: IOP measurements using Icare rebound tonometry, Tonopen, and Goldmann tonometry are in excellent agreement following vitreoretinal surgery. However, Icare overestimates at IOP ≥ 23 and underestimates at IOP <10 mm Hg.
Duke Scholars
Altmetric Attention Stats
Dimensions Citation Stats
Published In
DOI
EISSN
Publication Date
Volume
Start / End Page
Location
Related Subject Headings
- Vitreoretinal Surgery
- Tonometry, Ocular
- Reproducibility of Results
- Ophthalmology & Optometry
- Middle Aged
- Male
- Intraocular Pressure
- Humans
- Female
- Aged
Citation
Published In
DOI
EISSN
Publication Date
Volume
Start / End Page
Location
Related Subject Headings
- Vitreoretinal Surgery
- Tonometry, Ocular
- Reproducibility of Results
- Ophthalmology & Optometry
- Middle Aged
- Male
- Intraocular Pressure
- Humans
- Female
- Aged