Skip to main content

The Modified Ross Procedure with Prosthetic Graft Wrap Does Not Prevent Autograft Failure.

Publication ,  Journal Article
Wang, A; Ganapathi, AM; Wang, A; Hughes, GC
Published in: J Heart Valve Dis
November 2017

The modified Ross procedure, which involves replacement of the aortic valve with a pulmonary autograft root supported within a Dacron tube graft, was developed with the goal of preventing late autograft dilatation and associated aortic insufficiency. The case is reported of an adult patient who had a bicuspid aortic valve (BAV), underwent a modified Ross procedure, and developed severe aortic insufficiency within one year and subsequently required reoperation for aortic valve replacement. While advances have been made to increase the success of the Ross procedure via modifications to prevent aortic root dilatation, no modifications have yet been devised to improve the ability of the pulmonary valve to withstand systemic aortic pressures. The Ross procedure has significant advantages for children, but the risks and benefits should be carefully considered in adults, especially in those with BAV.

Duke Scholars

Published In

J Heart Valve Dis

ISSN

0966-8519

Publication Date

November 2017

Volume

26

Issue

6

Start / End Page

735 / 737

Location

England

Related Subject Headings

  • Respiratory System
  • Reoperation
  • Pulmonary Valve
  • Postoperative Complications
  • Polyethylene Terephthalates
  • Male
  • Humans
  • Heart Valve Prosthesis Implantation
  • Heart Valve Diseases
  • Bicuspid Aortic Valve Disease
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Wang, A., Ganapathi, A. M., & Hughes, G. C. (2017). The Modified Ross Procedure with Prosthetic Graft Wrap Does Not Prevent Autograft Failure. J Heart Valve Dis, 26(6), 735–737.
Wang, Alice, Asvin M. Ganapathi, Andrew Wang, and G Chad Hughes. “The Modified Ross Procedure with Prosthetic Graft Wrap Does Not Prevent Autograft Failure.J Heart Valve Dis 26, no. 6 (November 2017): 735–37.
Wang A, Ganapathi AM, Hughes GC. The Modified Ross Procedure with Prosthetic Graft Wrap Does Not Prevent Autograft Failure. J Heart Valve Dis. 2017 Nov;26(6):735–7.
Wang, Alice, et al. “The Modified Ross Procedure with Prosthetic Graft Wrap Does Not Prevent Autograft Failure.J Heart Valve Dis, vol. 26, no. 6, Nov. 2017, pp. 735–37.
Wang A, Ganapathi AM, Hughes GC. The Modified Ross Procedure with Prosthetic Graft Wrap Does Not Prevent Autograft Failure. J Heart Valve Dis. 2017 Nov;26(6):735–737.

Published In

J Heart Valve Dis

ISSN

0966-8519

Publication Date

November 2017

Volume

26

Issue

6

Start / End Page

735 / 737

Location

England

Related Subject Headings

  • Respiratory System
  • Reoperation
  • Pulmonary Valve
  • Postoperative Complications
  • Polyethylene Terephthalates
  • Male
  • Humans
  • Heart Valve Prosthesis Implantation
  • Heart Valve Diseases
  • Bicuspid Aortic Valve Disease