We present a real-time spectral-scanning frequencymodulated continuous wave (FMCW) 3D imaging and velocimetry system that can produce 3D depth maps at 33 Hz, with 48°×68° field of view (FOV) and 32.8-cm depth range. Each depth map consists of 507×500 pixels, with 0.095°×0.14° angular resolution and 2.82-mm depth resolution. The system employs a grating for beam steering and a telescope for angular FOV magnification. Quantitative depth, reflectivity, and axial velocity measurements of a static 3D printed depth variation target and amoving robotic arm are demonstrated.
Duke Scholars
Published In
Optics Letters
DOI
EISSN
1539-4794
ISSN
0146-9592
Publication Date
August 15, 2022
Volume
47
Issue
16
Start / End Page
4064 / 4067
Related Subject Headings
- Optics
- 5102 Atomic, molecular and optical physics
- 4009 Electronics, sensors and digital hardware
- 4006 Communications engineering
- 0906 Electrical and Electronic Engineering
- 0206 Quantum Physics
- 0205 Optical Physics
Citation
APA
Chicago
ICMJE
MLA
NLM
Zhang, J., Qian, R., Zhou, K. C., Viehland, C., Draelos, M., Dhalla, A. H., & Izatt, J. A. (2022). Real-time wide-field spectral-scanning FMCW coherent 3D imaging and velocimetry. Optics Letters, 47(16), 4064–4067. https://doi.org/10.1364/OL.463965
Zhang, J., R. Qian, K. C. Zhou, C. Viehland, M. Draelos, A. H. Dhalla, and J. A. Izatt. “Real-time wide-field spectral-scanning FMCW coherent 3D imaging and velocimetry.” Optics Letters 47, no. 16 (August 15, 2022): 4064–67. https://doi.org/10.1364/OL.463965.
Zhang J, Qian R, Zhou KC, Viehland C, Draelos M, Dhalla AH, et al. Real-time wide-field spectral-scanning FMCW coherent 3D imaging and velocimetry. Optics Letters. 2022 Aug 15;47(16):4064–7.
Zhang, J., et al. “Real-time wide-field spectral-scanning FMCW coherent 3D imaging and velocimetry.” Optics Letters, vol. 47, no. 16, Aug. 2022, pp. 4064–67. Scopus, doi:10.1364/OL.463965.
Zhang J, Qian R, Zhou KC, Viehland C, Draelos M, Dhalla AH, Izatt JA. Real-time wide-field spectral-scanning FMCW coherent 3D imaging and velocimetry. Optics Letters. 2022 Aug 15;47(16):4064–4067.
Published In
Optics Letters
DOI
EISSN
1539-4794
ISSN
0146-9592
Publication Date
August 15, 2022
Volume
47
Issue
16
Start / End Page
4064 / 4067
Related Subject Headings
- Optics
- 5102 Atomic, molecular and optical physics
- 4009 Electronics, sensors and digital hardware
- 4006 Communications engineering
- 0906 Electrical and Electronic Engineering
- 0206 Quantum Physics
- 0205 Optical Physics