A Faster Prostate MRI: Comparing a Novel Denoised, Single-Average T2 Sequence to the Conventional Multiaverage T2 Sequence Regarding Lesion Detection and PI-RADS Score Assessment.
BACKGROUND: The T2 w sequence is a standard component of a prostate MRI examination; however, it is time-consuming, requiring multiple signal averages to achieve acceptable image quality. PURPOSE/HYPOTHESIS: To determine whether a denoised, single-average T2 sequence (T2 -R) is noninferior to the standard multiaverage T2 sequence (T2 -S) in terms of lesion detection and PI-RADS score assessment. STUDY TYPE: Retrospective. POPULATION: A total of 45 males (age range 60-75 years) who underwent clinically indicated prostate MRI examinations, 21 of whom had pathologically proven prostate cancer. FIELD STRENGTH/SEQUENCE: A 3 T; T2 w FSE, DWI with ADC maps, and dynamic contrast-enhanced images with color-coded perfusion maps. T2 -R images were created from the raw data utilizing a single "average" with iterative denoising. ASSESSMENT: Nine readers randomly assessed complete exams including T2 -R and T2 -S images in separate sessions. PI-RADS version 2.1 was used. All readers then compared the T2 -R and T2 -S images side by side to evaluate subjective preference. An additional detailed image quality assessment was performed by three senior level readers. STATISTICAL TESTS: Generalized linear mixed effects models for differences in lesion detection, image quality features, and overall preference between T2 -R and T2 -S sequences. Intraclass correlation coefficients (ICC) were used to assess reader agreement for all comparisons. A significance threshold of P = 0.05 was used for all statistical tests. RESULTS: There was no significant difference between sequences regarding identification of lesions with PI-RADS ≥3 (P = 0.10) or PI-RADS score (P = 0.77). Reader agreement was excellent for lesion identification (ICC = 0.84). There was no significant overall preference between the two sequences regarding image quality (P = 0.07, 95% CI: [-0.23, 0.01]). Reader agreement was good regarding sequence preference (ICC = 0.62). DATA CONCLUSION: Use of single-average, denoised T2 -weighted images was noninferior in prostate lesion detection or PI-RADS scoring when compared to standard multiaverage T2 -weighted images. EVIDENCE LEVEL: 3. TECHNICAL EFFICACY: Stage 3.
Duke Scholars
Altmetric Attention Stats
Dimensions Citation Stats
Published In
DOI
EISSN
Publication Date
Volume
Issue
Start / End Page
Location
Related Subject Headings
- Retrospective Studies
- Prostatic Neoplasms
- Prostate
- Pelvis
- Nuclear Medicine & Medical Imaging
- Middle Aged
- Male
- Magnetic Resonance Imaging
- Humans
- Aged
Citation
Published In
DOI
EISSN
Publication Date
Volume
Issue
Start / End Page
Location
Related Subject Headings
- Retrospective Studies
- Prostatic Neoplasms
- Prostate
- Pelvis
- Nuclear Medicine & Medical Imaging
- Middle Aged
- Male
- Magnetic Resonance Imaging
- Humans
- Aged