Response-function measurement of an NE213 scintillator using the 2H(d, n)3He reaction
Publication
, Journal Article
Aksoy, A; Coban, A; Naqvi, AA; Khiari, FZ; Hanly, JM; Howell, CR; Tornow, W; Felsher, PD; Al-Ohali, MA; Walter, RL
Published in: Nuclear Inst. and Methods in Physics Research, A
January 1, 1994
The response function of a 12.5 cm diameter NE213 scintillator detector has been measured over neutron energies ranging from 4.9 to 16.6 MeV. Beams of monoenergetic neutrons were produced using the 2H(d, n)3He reaction. The response function is about 12% lower than previously reported values for a similar detector obtained using a continuous spectrum of neutrons from a 252Cf fission source. However, the present response function agrees with portions of data sets obtained in published work that used monoenergetic neutron source reactions. © 1994.
Duke Scholars
Published In
Nuclear Inst. and Methods in Physics Research, A
DOI
ISSN
0168-9002
Publication Date
January 1, 1994
Volume
337
Issue
2-3
Start / End Page
486 / 491
Related Subject Headings
- Nuclear & Particles Physics
- 5106 Nuclear and plasma physics
- 0299 Other Physical Sciences
- 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
- 0201 Astronomical and Space Sciences
Citation
APA
Chicago
ICMJE
MLA
NLM
Aksoy, A., Coban, A., Naqvi, A. A., Khiari, F. Z., Hanly, J. M., Howell, C. R., … Walter, R. L. (1994). Response-function measurement of an NE213 scintillator using the 2H(d, n)3He reaction. Nuclear Inst. and Methods in Physics Research, A, 337(2–3), 486–491. https://doi.org/10.1016/0168-9002(94)91118-5
Aksoy, A., A. Coban, A. A. Naqvi, F. Z. Khiari, J. M. Hanly, C. R. Howell, W. Tornow, P. D. Felsher, M. A. Al-Ohali, and R. L. Walter. “Response-function measurement of an NE213 scintillator using the 2H(d, n)3He reaction.” Nuclear Inst. and Methods in Physics Research, A 337, no. 2–3 (January 1, 1994): 486–91. https://doi.org/10.1016/0168-9002(94)91118-5.
Aksoy A, Coban A, Naqvi AA, Khiari FZ, Hanly JM, Howell CR, et al. Response-function measurement of an NE213 scintillator using the 2H(d, n)3He reaction. Nuclear Inst and Methods in Physics Research, A. 1994 Jan 1;337(2–3):486–91.
Aksoy, A., et al. “Response-function measurement of an NE213 scintillator using the 2H(d, n)3He reaction.” Nuclear Inst. and Methods in Physics Research, A, vol. 337, no. 2–3, Jan. 1994, pp. 486–91. Scopus, doi:10.1016/0168-9002(94)91118-5.
Aksoy A, Coban A, Naqvi AA, Khiari FZ, Hanly JM, Howell CR, Tornow W, Felsher PD, Al-Ohali MA, Walter RL. Response-function measurement of an NE213 scintillator using the 2H(d, n)3He reaction. Nuclear Inst and Methods in Physics Research, A. 1994 Jan 1;337(2–3):486–491.
Published In
Nuclear Inst. and Methods in Physics Research, A
DOI
ISSN
0168-9002
Publication Date
January 1, 1994
Volume
337
Issue
2-3
Start / End Page
486 / 491
Related Subject Headings
- Nuclear & Particles Physics
- 5106 Nuclear and plasma physics
- 0299 Other Physical Sciences
- 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
- 0201 Astronomical and Space Sciences