Experimental pulmonary infarction in dogs: a comparison of chest radiography and computed tomography.
Publication
, Journal Article
Lourie, GL; Pizzo, SV; Ravin, C; Putnam, C; Thompson, WM
Published in: Invest Radiol
1982
Transcatheter electrocoagulation of the pulmonary artery was used to successfully create experimental pulmonary infarcts in 15 to 16 dogs. The animals were evaluated from one to 13 weeks by chest radiography, computed tomography (CT), angiography, and pathologic examination. The abnormal densities in the dogs' lungs cleared in two to three weeks. The majority of the chest radiographs were normal in two weeks, and all were normal after three weeks. Prior to sacrifice, CT showed abnormal densities in the lungs in only two of eight animals. CT proved to be more sensitive than chest radiography for showing the densities in the lungs due to pulmonary infarction.
Duke Scholars
Published In
Invest Radiol
ISSN
0020-9996
Publication Date
1982
Volume
17
Issue
3
Start / End Page
224 / 232
Location
United States
Related Subject Headings
- Tomography, X-Ray Computed
- Pulmonary Embolism
- Nuclear Medicine & Medical Imaging
- Lung
- Electrocoagulation
- Dogs
- Disease Models, Animal
- Animals
- Angiography
- 3202 Clinical sciences
Citation
APA
Chicago
ICMJE
MLA
NLM
Lourie, G. L., Pizzo, S. V., Ravin, C., Putnam, C., & Thompson, W. M. (1982). Experimental pulmonary infarction in dogs: a comparison of chest radiography and computed tomography. Invest Radiol, 17(3), 224–232.
Lourie, G. L., S. V. Pizzo, C. Ravin, C. Putnam, and W. M. Thompson. “Experimental pulmonary infarction in dogs: a comparison of chest radiography and computed tomography.” Invest Radiol 17, no. 3 (1982): 224–32.
Lourie GL, Pizzo SV, Ravin C, Putnam C, Thompson WM. Experimental pulmonary infarction in dogs: a comparison of chest radiography and computed tomography. Invest Radiol. 1982;17(3):224–32.
Lourie, G. L., et al. “Experimental pulmonary infarction in dogs: a comparison of chest radiography and computed tomography.” Invest Radiol, vol. 17, no. 3, 1982, pp. 224–32.
Lourie GL, Pizzo SV, Ravin C, Putnam C, Thompson WM. Experimental pulmonary infarction in dogs: a comparison of chest radiography and computed tomography. Invest Radiol. 1982;17(3):224–232.
Published In
Invest Radiol
ISSN
0020-9996
Publication Date
1982
Volume
17
Issue
3
Start / End Page
224 / 232
Location
United States
Related Subject Headings
- Tomography, X-Ray Computed
- Pulmonary Embolism
- Nuclear Medicine & Medical Imaging
- Lung
- Electrocoagulation
- Dogs
- Disease Models, Animal
- Animals
- Angiography
- 3202 Clinical sciences