Skip to main content
Journal cover image

3He MRI in mouse models of asthma.

Publication ,  Journal Article
Driehuys, B; Walker, J; Pollaro, J; Cofer, GP; Mistry, N; Schwartz, D; Johnson, GA
Published in: Magn Reson Med
November 2007

In the study of asthma, a vital role is played by mouse models, because knockout or transgenic methods can be used to alter disease pathways and identify therapeutic targets that affect lung function. Assessment of lung function in rodents by available methods is insensitive because these techniques lack regional specificity. A more sensitive method for evaluating lung function in human asthma patients uses hyperpolarized (HP) (3)He MRI before and after bronchoconstriction induced by methacholine (MCh). We now report the ability to perform such (3)He imaging of MCh response in mice, where voxels must be approximately 3000 times smaller than in humans and (3)He diffusion becomes an impediment to resolving the airways. We show three-dimensional (3D) images that reveal airway structure down to the fifth branching and visualize ventilation at a resolution of 125 x 125 x 1000 microm(3). Images of ovalbumin (OVA)-sensitized mice acquired after MCh show both airway closure and ventilation loss. To also observe the MCh response in naive mice, we developed a non-slice-selective 2D protocol with 187 x 187 microm(2) resolution that was fast enough to record the MCh response and recovery with 12-s temporal resolution. The extension of (3)He MRI to mouse models should make it a valuable translational tool in asthma research.

Duke Scholars

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

November 2007

Volume

58

Issue

5

Start / End Page

893 / 900

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • Mice, Inbred C57BL
  • Mice, Inbred BALB C
  • Mice
  • Magnetic Resonance Imaging
  • Helium
  • Disease Models, Animal
  • Asthma
  • Animals
  • 4003 Biomedical engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Driehuys, B., Walker, J., Pollaro, J., Cofer, G. P., Mistry, N., Schwartz, D., & Johnson, G. A. (2007). 3He MRI in mouse models of asthma. Magn Reson Med, 58(5), 893–900. https://doi.org/10.1002/mrm.21306
Driehuys, Bastiaan, Julia Walker, Jim Pollaro, Gary P. Cofer, Nilesh Mistry, David Schwartz, and G Allan Johnson. “3He MRI in mouse models of asthma.Magn Reson Med 58, no. 5 (November 2007): 893–900. https://doi.org/10.1002/mrm.21306.
Driehuys B, Walker J, Pollaro J, Cofer GP, Mistry N, Schwartz D, et al. 3He MRI in mouse models of asthma. Magn Reson Med. 2007 Nov;58(5):893–900.
Driehuys, Bastiaan, et al. “3He MRI in mouse models of asthma.Magn Reson Med, vol. 58, no. 5, Nov. 2007, pp. 893–900. Pubmed, doi:10.1002/mrm.21306.
Driehuys B, Walker J, Pollaro J, Cofer GP, Mistry N, Schwartz D, Johnson GA. 3He MRI in mouse models of asthma. Magn Reson Med. 2007 Nov;58(5):893–900.
Journal cover image

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

November 2007

Volume

58

Issue

5

Start / End Page

893 / 900

Location

United States

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • Mice, Inbred C57BL
  • Mice, Inbred BALB C
  • Mice
  • Magnetic Resonance Imaging
  • Helium
  • Disease Models, Animal
  • Asthma
  • Animals
  • 4003 Biomedical engineering