Skip to main content

Errors in calculating the epicardial potential gradient field from unipolar voltage measurements during cardiac defibrillation

Publication ,  Journal Article
Idriss, SF; Ideker, RE; Wolf, PD; Smith, WM
Published in: Proceedings of the Annual Conference on Engineering in Medicine and Biology
December 1, 1991

An examination is made of the errors generated when calculating the magnitude of the epicardial potential gradient using voltages recorded from three unipolar electrodes in a fixed triangular geometry on the epicardial surface. The error sensitivity of the gradient calculation increases significantly with decreasing electrode separation and increasing common-mode voltage. For example, a mean error in calculated gradient magnitude of 67% results when measuring a 5 V/cm gradient at 50 V common-mode with 2 mm interelectrode spacing and random 1% voltage error. Optimization of interelectrode spacing and common-mode voltage to reduce overall error is essential for accurate measurement of low magnitude epicardial gradients.

Duke Scholars

Published In

Proceedings of the Annual Conference on Engineering in Medicine and Biology

ISSN

0589-1019

Publication Date

December 1, 1991

Volume

13

Issue

pt 2

Start / End Page

692 / 693
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Idriss, S. F., Ideker, R. E., Wolf, P. D., & Smith, W. M. (1991). Errors in calculating the epicardial potential gradient field from unipolar voltage measurements during cardiac defibrillation. Proceedings of the Annual Conference on Engineering in Medicine and Biology, 13(pt 2), 692–693.
Idriss, S. F., R. E. Ideker, P. D. Wolf, and W. M. Smith. “Errors in calculating the epicardial potential gradient field from unipolar voltage measurements during cardiac defibrillation.” Proceedings of the Annual Conference on Engineering in Medicine and Biology 13, no. pt 2 (December 1, 1991): 692–93.
Idriss SF, Ideker RE, Wolf PD, Smith WM. Errors in calculating the epicardial potential gradient field from unipolar voltage measurements during cardiac defibrillation. Proceedings of the Annual Conference on Engineering in Medicine and Biology. 1991 Dec 1;13(pt 2):692–3.
Idriss, S. F., et al. “Errors in calculating the epicardial potential gradient field from unipolar voltage measurements during cardiac defibrillation.” Proceedings of the Annual Conference on Engineering in Medicine and Biology, vol. 13, no. pt 2, Dec. 1991, pp. 692–93.
Idriss SF, Ideker RE, Wolf PD, Smith WM. Errors in calculating the epicardial potential gradient field from unipolar voltage measurements during cardiac defibrillation. Proceedings of the Annual Conference on Engineering in Medicine and Biology. 1991 Dec 1;13(pt 2):692–693.

Published In

Proceedings of the Annual Conference on Engineering in Medicine and Biology

ISSN

0589-1019

Publication Date

December 1, 1991

Volume

13

Issue

pt 2

Start / End Page

692 / 693