SU‐FF‐J‐58: Clinical Evaluation Using Digital Tomosynthesis for Positioning Verification of Breath‐Hold Liver Treatment

Publication ,  Conference
Fuller, J; wu, Q; Godfrey, D; Zhang, J; Wang, Z; Yoo, S; Yin, F
Published in: Medical Physics
January 1, 2007

Purpose: To demonstrate clinical feasibility of generating digital tomosynthesis (DTS) in a single breath‐hold (BH) period compared to multiple BH periods for CBCT acquisition and to examine on‐board BH‐DTS as an efficient alternative to BH‐CBCT for target localization of breath‐hold liver treatment. Methods & Materials: 3 patients receiving 3D conformal or IMRT treatments to the liver were retrospectively studied. Reference DTS images (RDTS) were generated using the BH planning CT and BH‐DTS images were reconstructed using the projection images acquired with BH‐CBCT. Matching between on‐board image set and reference image set was performed by (1) aligning bony anatomy near isocenter and (2) aligning target soft tissue using all image sets. Localization variations were calculated as the relative couch shifts in the vertical, longitudinal and lateral directions, as well as the relative couch rotations in pitch, yaw, and roll directions. Results: 10 – 40 degrees DTS images can be acquired within 1 single BH. Localization accuracy is in the range of 0.2 cm and 1.0 degree using the coronal‐view DTSs and is in the range of 0.35 cm and 1.6 degree using the for sagittal view DTS. The localization accuracy is comparable either using bony anatomy or using soft tissue. Conclusion: Rapid (< 10 sec.) BH‐DTS is more efficient than BH‐CBCT (> 5 min.) for daily 3D on‐board image guidance and localization of liver under breath‐hold radiation therapy. Partially supported by research grant from Varian Medical Systems. © 2007, American Association of Physicists in Medicine. All rights reserved.

Duke Scholars

Published In

Medical Physics

DOI

ISSN

0094-2405

Publication Date

January 1, 2007

Volume

34

Issue

6

Start / End Page

2381

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Fuller, J., wu, Q., Godfrey, D., Zhang, J., Wang, Z., Yoo, S., & Yin, F. (2007). SU‐FF‐J‐58: Clinical Evaluation Using Digital Tomosynthesis for Positioning Verification of Breath‐Hold Liver Treatment. In Medical Physics (Vol. 34, p. 2381). https://doi.org/10.1118/1.2760563
Fuller, J., Q. wu, D. Godfrey, J. Zhang, Z. Wang, S. Yoo, and F. Yin. “SU‐FF‐J‐58: Clinical Evaluation Using Digital Tomosynthesis for Positioning Verification of Breath‐Hold Liver Treatment.” In Medical Physics, 34:2381, 2007. https://doi.org/10.1118/1.2760563.
Fuller J, wu Q, Godfrey D, Zhang J, Wang Z, Yoo S, et al. SU‐FF‐J‐58: Clinical Evaluation Using Digital Tomosynthesis for Positioning Verification of Breath‐Hold Liver Treatment. In: Medical Physics. 2007. p. 2381.
Fuller, J., et al. “SU‐FF‐J‐58: Clinical Evaluation Using Digital Tomosynthesis for Positioning Verification of Breath‐Hold Liver Treatment.” Medical Physics, vol. 34, no. 6, 2007, p. 2381. Scopus, doi:10.1118/1.2760563.
Fuller J, wu Q, Godfrey D, Zhang J, Wang Z, Yoo S, Yin F. SU‐FF‐J‐58: Clinical Evaluation Using Digital Tomosynthesis for Positioning Verification of Breath‐Hold Liver Treatment. Medical Physics. 2007. p. 2381.

Published In

Medical Physics

DOI

ISSN

0094-2405

Publication Date

January 1, 2007

Volume

34

Issue

6

Start / End Page

2381

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences