Photon-counting cine-cardiac CT in the mouse.

Publication ,  Journal Article
Clark, DP; Holbrook, M; Lee, C-L; Badea, CT
Published in: PLoS One
2019

The maturation of photon-counting detector (PCD) technology promises to enhance routine CT imaging applications with high-fidelity spectral information. In this paper, we demonstrate the power of this synergy and our complementary reconstruction techniques, performing 4D, cardiac PCD-CT data acquisition and reconstruction in a mouse model of atherosclerosis, including calcified plaque. Specifically, in vivo cardiac micro-CT scans were performed in four ApoE knockout mice, following their development of calcified plaques. The scans were performed with a prototype PCD (DECTRIS, Ltd.) with 4 energy thresholds. Projections were sampled every 10 ms with a 10 ms exposure, allowing the reconstruction of 10 cardiac phases at each of 4 energies (40 total 3D volumes per mouse scan). Reconstruction was performed iteratively using the split Bregman method with constraints on spectral rank and spatio-temporal gradient sparsity. The reconstructed images represent the first in vivo, 4D PCD-CT data in a mouse model of atherosclerosis. Robust regularization during iterative reconstruction yields high-fidelity results: an 8-fold reduction in noise standard deviation for the highest energy threshold (relative to unregularized algebraic reconstruction), while absolute spectral bias measurements remain below 13 Hounsfield units across all energy thresholds and scans. Qualitatively, image domain material decomposition results show clear separation of iodinated contrast and soft tissue from calcified plaque in the in vivo data. Quantitatively, spatial, spectral, and temporal fidelity are verified through a water phantom scan and a realistic MOBY phantom simulation experiment: spatial resolution is robustly preserved by iterative reconstruction (10% MTF: 2.8-3.0 lp/mm), left-ventricle, cardiac functional metrics can be measured from iodine map segmentations with ~1% error, and small calcifications (615 μm) can be detected during slow moving phases of the cardiac cycle. Given these preliminary results, we believe that PCD technology will enhance dynamic CT imaging applications with high-fidelity spectral and material information.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

PLoS One

DOI

EISSN

1932-6203

Publication Date

2019

Volume

14

Issue

9

Start / End Page

e0218417

Location

United States

Related Subject Headings

  • X-Ray Microtomography
  • Tomography, X-Ray Computed
  • Photons
  • Phantoms, Imaging
  • Mice, Knockout
  • Mice
  • Image Interpretation, Computer-Assisted
  • Heart Function Tests
  • General Science & Technology
  • Four-Dimensional Computed Tomography
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Clark, D. P., Holbrook, M., Lee, C.-L., & Badea, C. T. (2019). Photon-counting cine-cardiac CT in the mouse. PLoS One, 14(9), e0218417. https://doi.org/10.1371/journal.pone.0218417
Clark, Darin P., Matthew Holbrook, Chang-Lung Lee, and Cristian T. Badea. “Photon-counting cine-cardiac CT in the mouse.PLoS One 14, no. 9 (2019): e0218417. https://doi.org/10.1371/journal.pone.0218417.
Clark DP, Holbrook M, Lee C-L, Badea CT. Photon-counting cine-cardiac CT in the mouse. PLoS One. 2019;14(9):e0218417.
Clark, Darin P., et al. “Photon-counting cine-cardiac CT in the mouse.PLoS One, vol. 14, no. 9, 2019, p. e0218417. Pubmed, doi:10.1371/journal.pone.0218417.
Clark DP, Holbrook M, Lee C-L, Badea CT. Photon-counting cine-cardiac CT in the mouse. PLoS One. 2019;14(9):e0218417.

Published In

PLoS One

DOI

EISSN

1932-6203

Publication Date

2019

Volume

14

Issue

9

Start / End Page

e0218417

Location

United States

Related Subject Headings

  • X-Ray Microtomography
  • Tomography, X-Ray Computed
  • Photons
  • Phantoms, Imaging
  • Mice, Knockout
  • Mice
  • Image Interpretation, Computer-Assisted
  • Heart Function Tests
  • General Science & Technology
  • Four-Dimensional Computed Tomography