Skip to main content

A miniaturized catheter 2-D array for real-time, 3-D intracardiac echocardiography.

Publication ,  Journal Article
Lee, W; Idriss, SF; Wolf, PD; Smith, SW
Published in: IEEE Trans Ultrason Ferroelectr Freq Control
October 2004

The design, fabrication, and characterization of a 112 channel, 5 MHz, two-dimensional (2-D) array transducer constructed on a six layer flexible polyimide interconnect circuit is described. The transducer was mounted in a 7 Fr (2.33 mm outside diameter) catheter for use in real-time intracardiac volumetric imaging. Two transducers were constructed: one with a single silver epoxy matching layer and the other without a matching layer. The center frequency and -6 dB fractional bandwidth of the transducer with a matching layer were 4.9 MHz and 31%, respectively. The 50 omega pitch-catch insertion loss was 80 dB, and the typical interelement crosstalk was -30 dB. The final element yield was greater than 97% for both transducers. The transducers were used to acquire real-time, 3-D images in an in vivo sheep model. We present in vivo images of cardiac anatomy obtained from within the coronary sinus, including the left and right atria, aorta, coronary arteries, and pulmonary veins. We also present images showing the manipulation of a separate electrophysiological catheter into the coronary sinus.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

IEEE Trans Ultrason Ferroelectr Freq Control

DOI

ISSN

0885-3010

Publication Date

October 2004

Volume

51

Issue

10

Start / End Page

1334 / 1346

Location

United States

Related Subject Headings

  • Transducers
  • Sheep
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Phantoms, Imaging
  • Miniaturization
  • Imaging, Three-Dimensional
  • Image Interpretation, Computer-Assisted
  • Image Enhancement
  • Heart
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Lee, W., Idriss, S. F., Wolf, P. D., & Smith, S. W. (2004). A miniaturized catheter 2-D array for real-time, 3-D intracardiac echocardiography. IEEE Trans Ultrason Ferroelectr Freq Control, 51(10), 1334–1346. https://doi.org/10.1109/tuffc.2004.1350962
Lee, Warren, Salim F. Idriss, Patrick D. Wolf, and Stephen W. Smith. “A miniaturized catheter 2-D array for real-time, 3-D intracardiac echocardiography.IEEE Trans Ultrason Ferroelectr Freq Control 51, no. 10 (October 2004): 1334–46. https://doi.org/10.1109/tuffc.2004.1350962.
Lee W, Idriss SF, Wolf PD, Smith SW. A miniaturized catheter 2-D array for real-time, 3-D intracardiac echocardiography. IEEE Trans Ultrason Ferroelectr Freq Control. 2004 Oct;51(10):1334–46.
Lee, Warren, et al. “A miniaturized catheter 2-D array for real-time, 3-D intracardiac echocardiography.IEEE Trans Ultrason Ferroelectr Freq Control, vol. 51, no. 10, Oct. 2004, pp. 1334–46. Pubmed, doi:10.1109/tuffc.2004.1350962.
Lee W, Idriss SF, Wolf PD, Smith SW. A miniaturized catheter 2-D array for real-time, 3-D intracardiac echocardiography. IEEE Trans Ultrason Ferroelectr Freq Control. 2004 Oct;51(10):1334–1346.

Published In

IEEE Trans Ultrason Ferroelectr Freq Control

DOI

ISSN

0885-3010

Publication Date

October 2004

Volume

51

Issue

10

Start / End Page

1334 / 1346

Location

United States

Related Subject Headings

  • Transducers
  • Sheep
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Phantoms, Imaging
  • Miniaturization
  • Imaging, Three-Dimensional
  • Image Interpretation, Computer-Assisted
  • Image Enhancement
  • Heart