Skip to main content
Journal cover image

Real-time 3D transesophageal echocardiography.

Publication ,  Journal Article
Pua, EC; Idriss, SF; Wolf, PD; Smith, SW
Published in: Ultrason Imaging
October 2004

Transesophageal echocardiography (TEE) is an essential diagnostic tool in patients with poor transthoracic echocardiographic windows or when detailed imaging of structures distant from the chest wall is necessary. A real-time 3D TEE probe has been fabricated in our laboratory in order to increase the amount of information available during a transesophageal procedure. The 1 cm diameter esophageal probe utilizes a 2-dimensional, 5 MHz array at its tip with a 6.3 mm diameter aperture, including 504 active channels. The array has a periodic vernier geometry with an element pitch of 0.18 mm, built onto a multilayer flexible (MLF) interconnect circuit. In order to accommodate 504 channels within the device, a 1 m long Gore MicroFlat cable was utilized for wiring the MLF to the corresponding system connectors. Pulse-echo tests in a water tank have yielded a -6 dB bandwidth of 25.3%. Fully connected to the system through 3 m of cable, the probe shows an average 50 omega insertion loss of-85 dB with a standard deviation of 4 dB, as determined through pitch-catch measurements for a sampling of 10 elements. Using the completed 3D TEE probe with the Volumetrics Medical Imaging 3D scanner, real-time volumetric images of in vivo canine cardiac anatomy have been acquired, displaying atrial views, mitral valve function and interventional catheter guidance.

Duke Scholars

Published In

Ultrason Imaging

DOI

ISSN

0161-7346

Publication Date

October 2004

Volume

26

Issue

4

Start / End Page

217 / 232

Location

England

Related Subject Headings

  • Phantoms, Imaging
  • Image Processing, Computer-Assisted
  • Equipment Design
  • Echocardiography, Transesophageal
  • Echocardiography, Three-Dimensional
  • Dogs
  • Animals
  • Acoustics
  • 4003 Biomedical engineering
  • 0903 Biomedical Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Pua, E. C., Idriss, S. F., Wolf, P. D., & Smith, S. W. (2004). Real-time 3D transesophageal echocardiography. Ultrason Imaging, 26(4), 217–232. https://doi.org/10.1177/016173460402600402
Pua, Eric C., Salim F. Idriss, Patrick D. Wolf, and S. W. Smith. “Real-time 3D transesophageal echocardiography.Ultrason Imaging 26, no. 4 (October 2004): 217–32. https://doi.org/10.1177/016173460402600402.
Pua EC, Idriss SF, Wolf PD, Smith SW. Real-time 3D transesophageal echocardiography. Ultrason Imaging. 2004 Oct;26(4):217–32.
Pua, Eric C., et al. “Real-time 3D transesophageal echocardiography.Ultrason Imaging, vol. 26, no. 4, Oct. 2004, pp. 217–32. Pubmed, doi:10.1177/016173460402600402.
Pua EC, Idriss SF, Wolf PD, Smith SW. Real-time 3D transesophageal echocardiography. Ultrason Imaging. 2004 Oct;26(4):217–232.
Journal cover image

Published In

Ultrason Imaging

DOI

ISSN

0161-7346

Publication Date

October 2004

Volume

26

Issue

4

Start / End Page

217 / 232

Location

England

Related Subject Headings

  • Phantoms, Imaging
  • Image Processing, Computer-Assisted
  • Equipment Design
  • Echocardiography, Transesophageal
  • Echocardiography, Three-Dimensional
  • Dogs
  • Animals
  • Acoustics
  • 4003 Biomedical engineering
  • 0903 Biomedical Engineering