Comparison of transbronchial lung biopsy yield between standard forceps and electrocautery hot forceps in swine.

Publication ,  Journal Article
Wahidi, MM; Shofer, SL; Sporn, TA; Ernst, A
Published in: Respiration
2010

BACKGROUND: Transbronchial lung biopsy (TBLB) is a commonly performed bronchoscopic procedure. Previous studies have suggested that larger biopsy forceps may improve diagnostic yield; however, the risk of bleeding associated with larger samples may be increased. The hot forceps are large forceps that are connected to an electrocautery system to minimize bleeding at the time of biopsy. OBJECTIVES: We evaluated the hot forceps for improvement in biopsy size and the number of sampled alveoli. METHODS: TBLBs were performed in 2 swine using one type of the forceps, followed by the other forceps 24 h later. Electrocautery was applied from closure of the forceps to retrieval of the sample. A blinded pathologist measured the size of each sample in its longest dimension and calculated the total alveolar content within the largest cross-section from each biopsy. RESULTS: A total of 74 biopsies were collected using each forceps type. Alveolar tissue was present in 25/74 and 26/74 of the biopsies using the hot and conventional forceps, respectively. There was no difference in the size of biopsies collected (2.10 +/- 1.10 vs. 1.83 +/- 0.94 mm; p = 0.164) or in the amount of alveoli per sample (343.2 +/- 402.4 vs. 439.5 +/- 463.5 alveoli; p = 0.433) for hot and conventional forceps, respectively. There was no artifact related to the use of electrocautery, and bleeding was minimal using either forceps system. CONCLUSIONS: The use of the electrocautery hot forceps for TBLB did not result in improvement of the size of biopsies or the amount of collected alveolar tissue in healthy pigs.

Duke Scholars

Published In

Respiration

DOI

EISSN

1423-0356

Publication Date

2010

Volume

79

Issue

2

Start / End Page

137 / 140

Location

Switzerland

Related Subject Headings

  • Swine
  • Respiratory System
  • Lung
  • Electrocoagulation
  • Cross-Over Studies
  • Bronchoscopy
  • Biopsy
  • Animals
  • 3201 Cardiovascular medicine and haematology
  • 1102 Cardiorespiratory Medicine and Haematology
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Wahidi, M. M., Shofer, S. L., Sporn, T. A., & Ernst, A. (2010). Comparison of transbronchial lung biopsy yield between standard forceps and electrocautery hot forceps in swine. Respiration, 79(2), 137–140. https://doi.org/10.1159/000235818
Wahidi, Momen M., Scott L. Shofer, Thomas A. Sporn, and Armin Ernst. “Comparison of transbronchial lung biopsy yield between standard forceps and electrocautery hot forceps in swine.Respiration 79, no. 2 (2010): 137–40. https://doi.org/10.1159/000235818.
Wahidi MM, Shofer SL, Sporn TA, Ernst A. Comparison of transbronchial lung biopsy yield between standard forceps and electrocautery hot forceps in swine. Respiration. 2010;79(2):137–40.
Wahidi, Momen M., et al. “Comparison of transbronchial lung biopsy yield between standard forceps and electrocautery hot forceps in swine.Respiration, vol. 79, no. 2, 2010, pp. 137–40. Pubmed, doi:10.1159/000235818.
Wahidi MM, Shofer SL, Sporn TA, Ernst A. Comparison of transbronchial lung biopsy yield between standard forceps and electrocautery hot forceps in swine. Respiration. 2010;79(2):137–140.
Journal cover image

Published In

Respiration

DOI

EISSN

1423-0356

Publication Date

2010

Volume

79

Issue

2

Start / End Page

137 / 140

Location

Switzerland

Related Subject Headings

  • Swine
  • Respiratory System
  • Lung
  • Electrocoagulation
  • Cross-Over Studies
  • Bronchoscopy
  • Biopsy
  • Animals
  • 3201 Cardiovascular medicine and haematology
  • 1102 Cardiorespiratory Medicine and Haematology