Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: our 1 year experience.

Publication ,  Journal Article
Chang, Z; Bowsher, J; Cai, J; Yoo, S; Wang, Z; Adamson, J; Ren, L; Yin, F-F
Published in: J Appl Clin Med Phys
July 5, 2012

American Association of Physicists in Medicine (AAPM) task group (TG) 142 has recently published a report to update recommendations of the AAPM TG 40 report and add new recommendations concerning medical accelerators in the era of image-guided radiation therapy (IGRT). The recommendations of AAPM TG 142 on IGRT are timely. In our institute, we established a comprehensive imaging QA program on a medical accelerator based on AAPM TG 142 and implemented it successfully. In this paper, we share our one-year experience and performance evaluation of an OBI capable linear accelerator, Novalis Tx, per TG 142 guidelines.

Duke Scholars

Published In

J Appl Clin Med Phys

DOI

EISSN

1526-9914

Publication Date

July 5, 2012

Volume

13

Issue

4

Start / End Page

3754

Location

United States

Related Subject Headings

  • Radiotherapy, Image-Guided
  • Radiotherapy Planning, Computer-Assisted
  • Quality Control
  • Particle Accelerators
  • Nuclear Medicine & Medical Imaging
  • Image Enhancement
  • Humans
  • Calibration
  • 5105 Medical and biological physics
  • 3208 Medical physiology
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Chang, Z., Bowsher, J., Cai, J., Yoo, S., Wang, Z., Adamson, J., … Yin, F.-F. (2012). Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: our 1 year experience. J Appl Clin Med Phys, 13(4), 3754. https://doi.org/10.1120/jacmp.v13i4.3754
Chang, Zheng, James Bowsher, Jing Cai, Sua Yoo, Zhiheng Wang, Justus Adamson, Lei Ren, and Fang-Fang Yin. “Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: our 1 year experience.J Appl Clin Med Phys 13, no. 4 (July 5, 2012): 3754. https://doi.org/10.1120/jacmp.v13i4.3754.
Chang Z, Bowsher J, Cai J, Yoo S, Wang Z, Adamson J, et al. Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: our 1 year experience. J Appl Clin Med Phys. 2012 Jul 5;13(4):3754.
Chang, Zheng, et al. “Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: our 1 year experience.J Appl Clin Med Phys, vol. 13, no. 4, July 2012, p. 3754. Pubmed, doi:10.1120/jacmp.v13i4.3754.
Chang Z, Bowsher J, Cai J, Yoo S, Wang Z, Adamson J, Ren L, Yin F-F. Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: our 1 year experience. J Appl Clin Med Phys. 2012 Jul 5;13(4):3754.

Published In

J Appl Clin Med Phys

DOI

EISSN

1526-9914

Publication Date

July 5, 2012

Volume

13

Issue

4

Start / End Page

3754

Location

United States

Related Subject Headings

  • Radiotherapy, Image-Guided
  • Radiotherapy Planning, Computer-Assisted
  • Quality Control
  • Particle Accelerators
  • Nuclear Medicine & Medical Imaging
  • Image Enhancement
  • Humans
  • Calibration
  • 5105 Medical and biological physics
  • 3208 Medical physiology