Skip to main content

Two dimensional arrays for 3-D ultrasound imaging

Publication ,  Journal Article
Smith, SW; Lee, W; Light, ED; Yen, JT; Wolf, P; Idriss, S
Published in: Proceedings of the IEEE Ultrasonics Symposium
December 1, 2002

Phased array ultrasound transducers have been fabricated in our laboratories at Duke University since 1970. In 1986, we began the development of 2-D arrays with a 20 × 20 element Mills cross array including 64 active channels operating at 1 MHz which produced the first real time 3-D ultrasound images. In our more recent arrays we have progressed to 108 × 108 = 11,664 elements in a series of transducers operating from 2.5 - 10 MHz. These were used in a commercial version of our Duke 3-D system developed by Volumetrics Medical Imaging for cardiac applications. The system scans a 65° 3-D pyramid at up to 60 volumes/sec and features five simultaneous slice images at any desired angle and depth as well as real time 3-D rendering, 3-D pulsed and color flow Doppler. We have also modified this scanner to produce the first real time 3-D rectilinear and curvilinear images using arrays of 256 × 256 = 65,536 elements operating at 5 MHz for vascular and small parts applications. Finally, we have developed catheter 2-D arrays for intra-cardiac 3-D ultrasound including 112 channels in a 2.2 mm lumen (7 French) operating at 5-7 MHz. In animal studies, these transducers have been applied to the guidance of cardiac interventional procedures including RF ablation, ECG mapping, surgical biopsy and atrial septal puncture.

Duke Scholars

Published In

Proceedings of the IEEE Ultrasonics Symposium

ISSN

1051-0117

Publication Date

December 1, 2002

Volume

2

Start / End Page

1545 / 1553
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Smith, S. W., Lee, W., Light, E. D., Yen, J. T., Wolf, P., & Idriss, S. (2002). Two dimensional arrays for 3-D ultrasound imaging. Proceedings of the IEEE Ultrasonics Symposium, 2, 1545–1553.
Smith, S. W., W. Lee, E. D. Light, J. T. Yen, P. Wolf, and S. Idriss. “Two dimensional arrays for 3-D ultrasound imaging.” Proceedings of the IEEE Ultrasonics Symposium 2 (December 1, 2002): 1545–53.
Smith SW, Lee W, Light ED, Yen JT, Wolf P, Idriss S. Two dimensional arrays for 3-D ultrasound imaging. Proceedings of the IEEE Ultrasonics Symposium. 2002 Dec 1;2:1545–53.
Smith, S. W., et al. “Two dimensional arrays for 3-D ultrasound imaging.” Proceedings of the IEEE Ultrasonics Symposium, vol. 2, Dec. 2002, pp. 1545–53.
Smith SW, Lee W, Light ED, Yen JT, Wolf P, Idriss S. Two dimensional arrays for 3-D ultrasound imaging. Proceedings of the IEEE Ultrasonics Symposium. 2002 Dec 1;2:1545–1553.

Published In

Proceedings of the IEEE Ultrasonics Symposium

ISSN

1051-0117

Publication Date

December 1, 2002

Volume

2

Start / End Page

1545 / 1553