Hyperpolarized 129 Xe gas transfer MRI: the transition from 1.5T to 3T.

Publication ,  Journal Article
Wang, Z; He, M; Bier, E; Rankine, L; Schrank, G; Rajagopal, S; Huang, Y-C; Kelsey, C; Womack, S; Mammarappallil, J; Driehuys, B
Published in: Magn Reson Med
December 2018

PURPOSE: Hyperpolarized 129 Xe MRI depicting 3D ventilation, interstitial barrier uptake, and transfer to red blood cells (RBCs) has emerged as a powerful new means of detecting pulmonary disease. However, given the challenging susceptibility environment of the lung, such gas transfer imaging has, thus far, only been implemented at 1.5T. Here, we seek to demonstrate the feasibility of Dixon-based 129 Xe gas transfer MRI at 3T. METHODS: Seven healthy subjects and six patients with pulmonary disorders were recruited to characterize 129 Xe spectral structure, optimize acquisition parameters, and acquire representative images. Imaging used randomized, gradient-spoiled 3D-radial encoding of 1000 gas (0.5° flip) and dissolved (20° flip) views, reconstructed into 3-mm isotropic voxels. The center of k-space was sampled when barrier and RBC compartments were 90° out of phase (TE90 ). A single dissolved phase spectrum was appended to the sequence to measure the global RBC-barrier ratio for Dixon-based decomposition. RESULTS: A 0.69 ms sinc was found to generate minimal off-resonance gas-phase excitation (3.0 ± 0.3% of the dissolved-phase), yielding a TE90  = 0.47 ± 0.02 ms. The RBC and barrier resonance frequencies were shifted by 217.6 ± 0.6 ppm and 197.8 ± 0.2 ppm. The RBC T 2 * was estimated to be ∼1.1 ms, and therefore each read-out was limited to 1.3 ms. 129 Xe gas and dissolved-phase images have sufficient SNR to produce gas transfer maps of similar quality and sensitivity to pathology, as previously obtained at 1.5T. CONCLUSIONS: Despite short dissolved-phase T 2 * , 129 Xe gas transfer MRI is feasible at 3T.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Magn Reson Med

DOI

EISSN

1522-2594

Publication Date

December 2018

Volume

80

Issue

6

Start / End Page

2374 / 2383

Location

United States

Related Subject Headings

  • alpha 1-Antitrypsin
  • Young Adult
  • Xenon Isotopes
  • Solubility
  • Respiration
  • Pulmonary Disease, Chronic Obstructive
  • Nuclear Medicine & Medical Imaging
  • Mutation
  • Middle Aged
  • Male
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Wang, Z., He, M., Bier, E., Rankine, L., Schrank, G., Rajagopal, S., … Driehuys, B. (2018). Hyperpolarized 129 Xe gas transfer MRI: the transition from 1.5T to 3T. Magn Reson Med, 80(6), 2374–2383. https://doi.org/10.1002/mrm.27377
Wang, Ziyi, Mu He, Elianna Bier, Leith Rankine, Geoffry Schrank, Sudarshan Rajagopal, Yuh-Chin Huang, et al. “Hyperpolarized 129 Xe gas transfer MRI: the transition from 1.5T to 3T.Magn Reson Med 80, no. 6 (December 2018): 2374–83. https://doi.org/10.1002/mrm.27377.
Wang Z, He M, Bier E, Rankine L, Schrank G, Rajagopal S, et al. Hyperpolarized 129 Xe gas transfer MRI: the transition from 1.5T to 3T. Magn Reson Med. 2018 Dec;80(6):2374–83.
Wang, Ziyi, et al. “Hyperpolarized 129 Xe gas transfer MRI: the transition from 1.5T to 3T.Magn Reson Med, vol. 80, no. 6, Dec. 2018, pp. 2374–83. Pubmed, doi:10.1002/mrm.27377.
Wang Z, He M, Bier E, Rankine L, Schrank G, Rajagopal S, Huang Y-C, Kelsey C, Womack S, Mammarappallil J, Driehuys B. Hyperpolarized 129 Xe gas transfer MRI: the transition from 1.5T to 3T. Magn Reson Med. 2018 Dec;80(6):2374–2383.
Journal cover image

Published In

Magn Reson Med

DOI

EISSN

1522-2594

Publication Date

December 2018

Volume

80

Issue

6

Start / End Page

2374 / 2383

Location

United States

Related Subject Headings

  • alpha 1-Antitrypsin
  • Young Adult
  • Xenon Isotopes
  • Solubility
  • Respiration
  • Pulmonary Disease, Chronic Obstructive
  • Nuclear Medicine & Medical Imaging
  • Mutation
  • Middle Aged
  • Male