Journal ArticlePhys Med Biol · July 16, 2024
Objective.To develop and benchmark a novel 3D dose verification technique consisting of polymer gel dosimetry (PGD) with cone-beam-CT (CBCT) readout through a two-institution study. The technique has potential for wide and robust applicability through reli ...
Full textLink to itemCite
Journal ArticleJ Appl Clin Med Phys · June 2024
PURPOSE: For individual targets of single isocenter multi-target (SIMT) Stereotactic radiosurgery (SRS), we assess dose difference between the treatment planning system (TPS) and independent Monte Carlo (MC), and demonstrate persistence into the pre-treatm ...
Full textLink to itemCite
Journal ArticleAdv Radiat Oncol · January 2024
PURPOSE: Genetic variants affecting the radiation response protein ataxia-telangiectasia mutated (ATM) have been associated with increased adverse effects of radiation but also with improved local control after conventional radiation therapy. However, it i ...
Full textLink to itemCite
ConferenceJournal of Physics: Conference Series · January 1, 2024
A comprehensive 3D dosimetry system consisting of the ClearView™ 3D dosimeter, VistaScan™ optical CT scanner, and VistaAce™ analysis software is commercially available and has the potential to be a strong verification tool with widespread applications. The ...
Full textCite
Journal ArticlePhys Med Biol · September 13, 2023
Objective.To develop a deep ensemble learning (DEL) model with radiomics spatial encoding execution for improved glioma segmentation accuracy using multi-parametric magnetic resonance imaging (mp-MRI).Approach.This model was developed using 369 glioma pati ...
Full textLink to itemCite
Journal ArticleZ Med Phys · September 7, 2023
BACKGROUND: Dosimetric validation of single isocenter multi-target radiosurgery plans is difficult due to conditions of electronic disequilibrium and the simultaneous irradiation of multiple off-axis lesions dispersed throughout the volume. Here we report ...
Full textLink to itemCite
Journal ArticleMed Phys · September 2023
BACKGROUND: Many commercial tools are available for plan-specific quality assurance (QA) of radiotherapy plans, with their functionality assessed in isolation. However, multiple QA tools are required to review the full range of potential errors. It is impo ...
Full textLink to itemCite
Journal ArticleMed Phys · September 2023
BACKGROUND: Sophisticated modern radiation therapy treatments require comprehensive validation in 3D. PURPOSE: Investigation and characterization of a novel 3D dosimetry system consisting of ClearView radiochromic gel dosimeters (commercially available fro ...
Full textLink to itemCite
Journal ArticleBiomed Phys Eng Express · March 7, 2023
Objective. Dose calculation in lung stereotactic body radiation therapy (SBRT) is challenging due to the low density of the lungs and small volumes. Here we assess uncertainties associated with tissue heterogeneities using different dose calculation algori ...
Full textLink to itemCite
Journal ArticleAdvances in radiation oncology · March 2023
PurposeHypofractionated stereotactic radiosurgery (HF-SRS) with or without surgical resection is potentially a preferred treatment for larger or symptomatic brain metastases (BMs). Herein, we report clinical outcomes and predictive factors followi ...
Full textCite
Journal ArticleJ Appl Clin Med Phys · November 2022
We demonstrate a virtual pretreatment patient-specific QA (PSQA) procedure that is capable of quantifying dosimetric effect on patient anatomy for both intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). A machine learning ...
Full textLink to itemCite
Journal ArticleSoftwareX · July 1, 2022
We present an open-source artificial intelligence (AI) model that predicts machine parameters at treatment delivery using trajectory files from prior patients. Predictive models for IMRT and VMAT utilized a boosted and bagged tree, respectively, and predic ...
Full textCite
ConferenceJournal of Physics: Conference Series · January 24, 2022
We report our progress towards developing a clinical application of NIPAM kV-CBCT dosimetry. The goal is to develop a practical kV-MV isocenter verification test for which the measurement and analysis can be carried out quickly (within an hour), and that e ...
Full textCite
ConferenceAdv Radiat Oncol · 2022
PURPOSE: Stereotactic radiosurgery (SRS) is a highly effective therapy for newly diagnosed brain metastases. Prophylactic antiepileptic drugs are no longer routinely used in current SRS practice, owing to a perceived low overall frequency of new-onset seiz ...
Full textLink to itemCite
Journal ArticlePract Radiat Oncol · 2022
PURPOSE: To explore implications of various plan normalizations when implementing a linear Boltzmann transport equation solver dose calculation algorithm (LBTE) for lung stereotactic body radiation therapy (SBRT). METHODS AND MATERIALS: Eighty-seven plans ...
Full textLink to itemCite
Journal ArticleJ Appl Clin Med Phys · July 2021
PURPOSE: In this study, we evaluate and compare single isocenter multiple target VMAT (SIMT) and Conformal Arc Informed VMAT (CAVMAT) radiosurgery's sensitivity to uncertainties in dosimetric leaf gap (DLG) and treatment delivery. CAVMAT is a novel plannin ...
Full textLink to itemCite
Journal ArticleCureus · June 2021
Brain metastases are a common complication for patients diagnosed with cancer. As stereotactic radiosurgery (SRS) becomes a more prevalent treatment option for patients with many brain metastases, further research is required to better characterize the abi ...
Full textOpen AccessLink to itemCite
Journal ArticleMed Phys · March 2021
PURPOSE: Multileaf collimator (MLC) delivery discrepancy between planned and actual (delivered) positions have detrimental effect on the accuracy of dose distributions for both IMRT and VMAT. In this study, we evaluated the consistency of MLC delivery disc ...
Full textLink to itemCite
Journal ArticleAdv Radiat Oncol · 2021
PURPOSE: To examine the effectiveness and safety of single-isocenter multitarget stereotactic radiosurgery using a volume-adapted dosing strategy in patients with 4 to 10 brain metastases. METHODS AND MATERIALS: Adult patients with 4 to 10 brain metastases ...
Full textLink to itemCite
Journal ArticleBiomed Phys Eng Express · December 4, 2020
Purpose:Trajectory log files are increasingly being utilized clinically for machine and patient specific QA. The process of converting the DICOM-RT plan to a deliverable trajectory by the linac control software introduces some uncertainty that is inherentl ...
Full textLink to itemCite
Journal ArticleCancer · April 1, 2020
Brain metastasis (BM), the most common adult brain tumor, develops in 20% to 40% of patients with late-stage cancer and traditionally are associated with a poor prognosis. The management of patients with BM has become increasingly complex because of new an ...
Full textLink to itemCite
Journal ArticleMed Phys · March 2020
PURPOSE: To develop and demonstrate a comprehensive method to directly measure radiation isocenter uncertainty and coincidence with the cone-beam computed tomography (kV-CBCT) imaging coordinate system that can be carried out within a typical quality assur ...
Full textLink to itemCite
Journal ArticleJ Radiosurg SBRT · 2020
AAPM TG-218 provides recommendations for standard IMRT pre-treatment QA without giving specifics for stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT). In light of this, our purpose is to report our experience with applying TG-218 r ...
Link to itemCite
Journal ArticlePhys Med Biol · November 21, 2019
RECA (Radiotherapy enhanced with Cherenkov photo-activation) is a proposed treatment where the anti-cancer drug psoralen is photo-activated in situ by UVA (Ultraviolet A, 320-400 nm) Cherenkov light (CL) produced directly by the treatment beam itself. In t ...
Full textLink to itemCite
ConferenceJournal of Physics: Conference Series · August 29, 2019
We investigated the feasibility of using N-isopropylacrylamide (NIPAM) dosimeters with x-ray CT to verify radiosurgery dose. Dosimeters were prepared at one facility and shipped to a second facility for irradiation. A simulation CT was acquired and plans p ...
Full textCite
Journal ArticleInt J Radiat Oncol Biol Phys · April 1, 2019
PURPOSE: To demonstrate proof of principle of visualizing delivered 3-dimensional (3D) dose distribution using kilovoltage (kv) cone beam computed tomography (CBCT) mounted onboard a linear accelerator. We apply this technique as a unique end-to-end verifi ...
Full textLink to itemCite
Journal ArticleJ Radiosurg SBRT · 2019
PURPOSE: Follow-up imaging after stereotactic radiosurgery (SRS) is crucial to identify salvageable brain metastases (BM) recurrence. As optimal imaging intervals are poorly understood, we sought to build a predictive model for time to intracranial progres ...
Link to itemCite
Journal ArticleJ Radiosurg SBRT · 2019
PURPOSE: Single-isocenter multi-target (SIMT) volumetric modulated arc therapy (VMAT) is primarily limited to linear accelerators utilizing 2.5 mm leaf width MLCs. We explore feasibility of applying this technique to linear accelerators utilizing MLCs with ...
Open AccessLink to itemCite
Journal ArticleMed Phys · July 2018
PURPOSE: Cherenkov light during MV radiotherapy has recently found imaging and therapeutic applications but is challenged by relatively low fluence. Our purpose is to investigate the feasibility of increasing Cherenkov light production during MV radiothera ...
Full textLink to itemCite
Journal ArticleInt J Radiat Oncol Biol Phys · March 1, 2018
PURPOSE: This work investigates a new approach to enhance radiotherapy through a photo therapeutic agent activated by Cherenkov light produced from the megavoltage photon beam. The process is termed Radiotherapy Enhanced with Cherenkov photo-Activation (RE ...
Full textOpen AccessLink to itemCite
Journal ArticleTechnol Cancer Res Treat · December 2017
Our purpose was to investigate polymeric gels for use as a highly transparent radiotherapy bolus and determine the relevant physical and dosimetric properties. We first quantified tensile properties (maximum stress, strain, and Young modulus) for various p ...
Full textLink to itemCite
Journal ArticleBiomedical Physics and Engineering Express · May 25, 2017
X-ray psoralen activated cancer therapy (X-PACT) is a new therapeutic approach that has been shown to induce tumor cell apoptosis and cytotoxicity in vitro, and slow tumor growth in BALB/c mice with syngeneic 4T1 tumors. X-PACT is accomplished by injection ...
Full textCite
Journal ArticleJ Appl Clin Med Phys · January 2017
PURPOSE: TrueBeams equipped with the 40 × 30 cm2 Electronic Portal Imaging Devices (EPIDs) are prone to image saturation at the image center when used with flattening filter free (FFF) photon energies. While cine imaging during treatment may not saturate b ...
Full textLink to itemCite
Journal ArticlePract Radiat Oncol · 2017
PURPOSE: Bolus-tracked multiphasic contrast computed tomography (CT) is often used in diagnostic radiology to enhance the visibility of pancreas tumors, but is uncommon in radiation therapy pancreas CT simulation, and its impact on gross tumor volume (GTV) ...
Full textLink to itemCite
Journal ArticleAdv Radiat Oncol · 2017
INTRODUCTION: Due to the neurocognitive side effects of whole brain radiation therapy (WBRT), stereotactic radiosurgery (SRS) is being used with increasing frequency. The use of SRS is expanding for patients with multiple (>4) brain metastases (BM). This s ...
Full textOpen AccessLink to itemCite
Journal ArticleMed Phys · October 2016
PURPOSE: The recent development of multifocal stereotactic radiosurgery (SRS) using a single isocenter volumetric modulated arc theory (VMAT) technique warrants a re-examination of the quality assurance (QA) tolerances for routine mechanical QA recommended ...
Full textLink to itemCite
Journal ArticleMed Phys · June 2016
PURPOSE: This work investigates X-PACT (X-ray Psoralen Activated Cancer Therapy): a new approach for the treatment of cancer. X-PACT utilizes psoralen, a potent anti-cancer therapeutic with immunogenic anti-cancer potential. Psoralen therapies have been li ...
Full textLink to itemCite
Journal ArticleMed Phys · June 2016
PURPOSE: X-PACT is an experimental cancer therapy where kV x-rays are used to photo-activate anti-cancer therapeutics through phosphor intermediaries (phosphors that absorb x-rays and re-radiate as UV light). Clinical trials in pet dogs are currently under ...
Full textLink to itemCite
Journal ArticleMed Phys · June 2016
PURPOSE: Varian's electronic portal imaging device (EPID) based portal dosimetry tool is a popular and effective means of performing IMRT QA. EPIDs for older models of the TrueBeam accelerator utilize a 40cmx30cm Image Detection Unit (IDU) that saturates a ...
Full textLink to itemCite
Journal ArticleMed Phys · June 2016
PURPOSE: For multiple mets radiosurgery, it is advantageous to use VMAT with a single isocenter for the ease in planning and efficiency in delivery. Insightful pre-treatment QA for these cases is difficult to obtain because (1) target size is often small a ...
Full textLink to itemCite
ConferenceMedical Physics · June 2016
Purpose:Flattening filter free photon energies are commonly used for high dose treatments such as SBRT, where localization accuracy is essential. Often, MV cine imaging may be employed to verify correct localizati ...
Full textCite
Journal ArticleJ Appl Clin Med Phys · January 8, 2016
We investigate the sensitivity of IMRT commissioning using the TG-119 C-shape phantom and credentialing with the IROC head and neck phantom to treatment planning system commissioning errors. We introduced errors into the various aspects of the commissionin ...
Full textOpen AccessLink to itemCite
ConferencePract Radiat Oncol · 2016
OBJECTIVE: Our purpose was to address challenges associated with single-isocenter radiosurgery for multiple intracranial targets (SIRMIT) including increased sensitivity to rotational uncertainties (resulting from distance of the targets from isocenter) as ...
Full textLink to itemCite
Journal ArticlePract Radiat Oncol · 2016
PURPOSE: To evaluate the feasibility of adaptive planning using positron emission tomography-computed tomography (PET-CT) in locally advanced non-small cell lung cancer. METHODS AND MATERIALS: Patients with locally advanced non-small cell lung cancer recei ...
Full textLink to itemCite
Journal ArticleJ Appl Clin Med Phys · January 2016
We investigate the sensitivity of IMRT commissioning using the TG-119 C-shape phantom and credentialing with the IROC head and neck phantom to treatment planning system commissioning errors. We introduced errors into the various aspects of the commissionin ...
Full textLink to itemCite
Journal ArticlePLoS One · 2016
This work investigates X-PACT (X-ray Psoralen Activated Cancer Therapy): a new approach for the treatment of solid cancer. X-PACT utilizes psoralen, a potent anti-cancer therapeutic with current application to proliferative disease and extracorporeal photo ...
Full textOpen AccessLink to itemCite
Journal ArticlePhys Med Biol · June 21, 2015
Increased interest regarding sensitivity of pre-treatment intensity modulated radiotherapy and volumetric modulated arc radiotherapy (VMAT) quality assurance (QA) to delivery errors has led to the development of dose-volume histogram (DVH) based analysis. ...
Full textLink to itemCite
Journal ArticleMed Phys · June 2015
PURPOSE: To develop a robust MRI sequence to measure BOLD breath hold induced contrast in context of breast radiotherapy. METHODS: Two sequences were selected from prior studies as candidates to measure BOLD contrast attributable to breath holding within t ...
Full textLink to itemCite
Journal ArticleMed Phys · June 2015
PURPOSE: Psoralen is a UV-light activated anti-cancer biotherapeutic used for treating skin lesions (PUVA) and advanced cutaneous T-cell lymphoma (ECP). To date psoralen has not been used to treat deep seated tumors due to difficulty in generating UV-light ...
Full textLink to itemCite
Journal ArticlePLoS One · 2015
BACKGROUND: Despite the clinical benefit of whole brain radiotherapy (WBRT), patients and physicians are concerned by the long-term impact on cognitive functioning. Many studies investigating the molecular and cellular impact of WBRT have used rodent model ...
Full textLink to itemCite
Journal ArticleMed Phys · July 2014
PURPOSE: To investigate the feasibility of and challenges yet to be addressed to measure dose from low energy (effective energy <50 keV) brachytherapy sources (Pd-103, Cs-131, and I-125) using polyurethane based 3D dosimeters with optical CT. METHODS: The ...
Full textLink to itemCite
Journal ArticleMed Phys · June 2014
PURPOSE: To test the ability of the TG-119 commissioning process and RPC credentialing to detect errors in the commissioning process for a commercial Treatment Planning System (TPS). METHODS: We introduced commissioning errors into the commissioning proces ...
Full textLink to itemCite
Journal ArticleMed Phys · June 2014
PURPOSE: There is increased interest in the Radiation Oncology Physics community regarding sensitivity of pre-treatment IMRT/VMAT QA to delivery errors. Consequently, tools mapping pre-treatment QA to the patient DVH have been developed. However, the quant ...
Full textLink to itemCite
Journal ArticleTechnol Cancer Res Treat · February 2014
Stereotactic radiosurgery (SRS) has been an effective treatment method for brain tumors; however, few data are available regarding radiation-induced white matter (WM) damage by SRS. In this work, diffusion tensor imaging (DTI) was used to investigate WM ch ...
Full textLink to itemCite
Journal ArticlePhys Med Biol · October 7, 2013
Volumetric modulated arc therapy (VMAT) is a relatively new treatment modality for dynamic photon radiation therapy. Pre-treatment quality assurance (QA) is necessary and many efforts have been made to apply electronic portal imaging device (EPID)-based IM ...
Full textLink to itemCite
Journal ArticleMed Phys · June 2013
PURPOSE: Recent innovations in 3D dosimetry include deformable polyurethane dosimeters (PRESAGE) and high resolution optical CT (∼50 microns). These developments enable 3D dosimetry in deformation conditions present during prostate LDR brachytherapy. Howev ...
Full textLink to itemCite
ConferenceMed Phys · June 2013
PURPOSE: To evaluate the accuracy and sensitivity of a patient clinical objective IMRT QA tool using a 3D diode array. METHODS: A 3D QA device (Delta4, Scandidos Inc.) with 2 orthogonal diode array planes was used for IMRT QA. The diode spacing is 5mm in c ...
Full textLink to itemCite
ConferenceMed Phys · June 2013
PURPOSE: Volumetric modulated arc therapy (VMAT) is a relatively new treatment modality for dynamic photon radiation therapy. Pre-treatment quality assurance (QA) is necessary and many efforts have been taken to apply electronic portal imaging device (EPID ...
Full textLink to itemCite
Journal ArticleMed Phys · June 2013
PURPOSE: Pre-treatment IMRT and VMAT QA techniques are often commissioned without knowledge of their sensitivity to clinically relevant delivery errors. The purpose of this work is to develop a method to quantify the sensitivity and specificity of pre-trea ...
Full textLink to itemCite
ConferenceMed Phys · June 2013
PURPOSE: Correct MLC modeling is essential to the accurate IMRT delivery. Most TPSs use simplified models with parameters of leaf transmission (LT) and dynamic leaf gap (DLG). The common way to determine them is through extrapolation from measurements. In ...
Full textLink to itemCite
ConferenceJ Phys Conf Ser · 2013
We describe a method to directly measure the radial dose and anisotropy functions of brachytherapy sources using polyurethane based dosimeters read out with optical CT. We measured the radial dose and anisotropy functions for a Cs-137 source using a PRESAG ...
Full textLink to itemCite
Journal ArticleMed Phys · November 2012
PURPOSE: A TrueBeam linear accelerator (TB-LINAC) is designed to deliver traditionally flattened and flattening-filter-free (FFF) beams. Although it has been widely adopted in many clinics for patient treatment, limited information is available related to ...
Full textLink to itemCite
Journal ArticlePhys Med Biol · October 21, 2012
Featured Publication
We propose a method to incorporate independent verification of gantry angle for electronic portal imaging device (EPID)-based pre-treatment quality assurance (QA) of clinical volumetric modulated arc therapy (VMAT) plans. Gantry angle is measured using pro ...
Full textLink to itemCite
Journal ArticleJ Appl Clin Med Phys · July 5, 2012
Featured Publication
American Association of Physicists in Medicine (AAPM) task group (TG) 142 has recently published a report to update recommendations of the AAPM TG 40 report and add new recommendations concerning medical accelerators in the era of image-guided radiation th ...
Full textOpen AccessLink to itemCite
Journal ArticleMed Phys · July 2012
Featured Publication
PURPOSE: To determine the geometric and dose attenuation characteristics of a new commercially available CT-compatible LDR tandem and ovoid (T&O) applicator using Monte Carlo calculation and 3D dosimetry. METHODS: For geometric characterization, we quantif ...
Full textLink to itemCite
Journal ArticleMed Phys · June 2012
PURPOSE: To determine the characteristics of a new commercially available CT-compatible LDR Tandem and Ovoid (T&O) applicator using 3D dosimetry. METHODS: We characterized source attenuation through the asymmetric gold shielding in the buckets by measuring ...
Full textLink to itemCite
Journal ArticleMed Phys · June 2012
INTRODUCTION: A TrueBeam linear accelerator (TB-LINAC) is designed to deliver standard flattened and flattening-filter-free (FFF) beams. In our institute, three TB-LINAC units are installed. In this work, composite data of the three units and multi-unit co ...
Full textLink to itemCite
Journal ArticleInt J Radiat Oncol Biol Phys · January 1, 2012
Featured Publication
PURPOSE: Several recent series evaluating external beam accelerated partial breast irradiation (PBI) have reported adverse cosmetic outcomes, possibly related to large volumes of normal tissue receiving near-prescription doses. We hypothesized that deliver ...
Full textLink to itemCite
Journal ArticleJournal of Applied Clinical Medical Physics · January 1, 2012
American Association of Physicists in Medicine (AAPM) task group (TG) 142 has recently published a report to update recommendations of the AAPM TG 40 report and add new recommendations concerning medical accelerators in the era of image-guided radiation th ...
Full textCite
Journal ArticleComput Biol Med · October 2011
Featured Publication
We propose a method to quantify superior-inferior (SI) motion of a rigid target using the 3D contour from free-breathing CT (FBCT). The technique utilizes similarity between 2D contours (Jaccard Index) and a population based density function for probabilit ...
Full textLink to itemCite
Journal ArticleInt J Radiat Oncol Biol Phys · June 1, 2011
Featured Publication
PURPOSE: To quantify the dosimetric effect and margins required to account for prostate intrafractional translation and residual setup error in a cone beam computed tomography (CBCT)-guided hypofractionated radiotherapy protocol. METHODS AND MATERIALS: Pro ...
Full textLink to itemCite
ConferenceMedical Physics · January 1, 2011
Purpose: In VMAT, the dose rate, MLC position, and gantry angle change simultaneously, it is important they follow their predefined trajectories to ensure correct dose delivery. Our purpose is to develop an efficient VMAT QA strategy using EPID that is cap ...
Full textCite
Chapter · January 1, 2011
In current standard radiation therapy process, patient anatomy is represented by the snapshot of computed tomography (CT) images at the simulation for treatment planning. The planned radiation dose distribution, obtained from either three-dimensional (3D) ...
Full textCite
Journal ArticleInt J Radiat Oncol Biol Phys · December 1, 2010
Featured Publication
PURPOSE: To describe prostate intrafraction motion using kilovoltage fluoroscopy at treatment delivery for a hypofractionated radiotherapy protocol. METHODS AND MATERIALS: Kilovoltage images were acquired during treatment delivery, as well as pre- and post ...
Full textLink to itemCite
Journal ArticleInt J Radiat Oncol Biol Phys · December 1, 2010
Featured Publication
PURPOSE: To investigate potential benefits of adaptive strategies for managing prostate intrafractional uncertainties when interfraction motion is corrected online. METHODS AND MATERIALS: Prostate intrafraction motion was measured using kV fluoroscopy duri ...
Full textLink to itemCite
Journal ArticleMed Phys · November 2010
Featured Publication
PURPOSE: To evaluate the feasibility of acquiring maximum intensity projection (MIP) images using a novel slice-stacking MRI (SS-MRI) technique. METHODS: The proposed technique employed a steady state acquisition sequence to image multiple axial slices. At ...
Full textLink to itemCite
ConferenceMedical Physics · January 1, 2010
Purpose: To propose a novel method of acquiring Maximum Intensity Projection (MIP) images using multi‐slice cine MRI, termed as MRI‐MIP, and to evaluate its feasibility in quantifying motion magnitude. Materials and Methods: MRI‐MIP images are acquired usi ...
Full textCite
ConferenceMedical Physics · January 1, 2010
Purpose: A 15–30s Breath Hold (BH) is often used in radiation therapy for breast cancer patients to minimize heart dose, however its effect on tumor oxygenation and radiosensitivity is unknown. The purpose of this study is to utilize published data on the ...
Full textCite
Journal ArticleInt J Radiat Oncol Biol Phys · September 1, 2009
Featured Publication
PURPOSE: To evaluate the ability of rectal filling, bladder filling, and prostate localization from pre- and posttreatment volumetric imaging to predict prostate intrafraction motion. METHODS AND MATERIALS: Pre- and posttreatment cone beam computed tomogra ...
Full textLink to itemCite
Journal ArticlePhys Med Biol · January 7, 2009
Featured Publication
Monoscopic kV imaging during radiotherapy has been recently implemented for prostate intrafraction motion evaluation. However, the accuracy of 3D localization techniques from monoscopic imaging of prostate and the effect of acquisition parameters on the 3D ...
Full textLink to itemCite
ConferenceMedical Physics · January 1, 2009
Purpose: Many dosimetric evaluations of prostate intrafraction motion disregard effects of treatment duration and translations of the surrounding body per fraction. However the probability of motion has been shown to increase with time and image guidance s ...
Full textCite
ConferenceMedical Physics · January 1, 2009
Purpose: Prostate intrafraction motion has been shown to be patient specific; however most current compensation strategies are population wide. We evaluate the feasibility of applying margins based on a subpopulation of patients with similar intrafraction ...
Full textCite
Journal ArticleMed Phys · May 2008
Featured Publication
Margin reduction for prostate radiotherapy is limited by uncertainty in prostate localization during treatment. We investigated the feasibility and accuracy of measuring prostate intrafraction motion using kV fluoroscopy performed simultaneously with radio ...
Full textLink to itemCite
ConferenceMedical Physics · January 1, 2008
Purpose: Recent studies of prostate intrafraction motion have been inconclusive. One cine‐MRI study demonstrated that pre‐treatment rectal filling status is a significant predictor of intrafraction motion magnitude. However, studies using the Calypso syste ...
Full textCite
ConferenceMedical Physics · January 1, 2008
Purpose: Commercially available gantry mounted kV imagers are currently restricted to manual fluoroscopy acquisitions with fixed mAs & frame rate, limiting use of fluoroscopy for prostate intrafraction motion measurement. For consideration in future acquis ...
Full textCite
Journal ArticleWest Indian Med J · December 2007
Group B streptococcus is the most common cause of neonatal sepsis in the United States of America (USA). This study was undertaken to determine the contribution of group B streptococcus to neonatal septicaemia in Antigua and Barbuda. From 1994 to 2002, the ...
Link to itemCite
Journal ArticleMedical Physics · January 1, 2007
Purpose: Margin reduction for prostate radiotherapy is limited by uncertainty in prostate localization during treatment. We investigate the feasibility and accuracy of measuring prostate intrafraction motion using kV fluoroscopy performed simultaneously wi ...
Full textCite
Journal ArticleUltrasonics · December 22, 2006
Featured Publication
The objective was to use multiple paths through the slurry to determine the lowest concentration that provided accurate attenuation measurements and to measure the velocity of sound through an effective long path. Ultrasonic attenuation measurements were o ...
Full textLink to itemCite
Journal ArticleUltrasonics · December 22, 2006
Featured Publication
We have developed an on-line computer-controlled sensor, based on ultrasound reflection measurements, to determine the product of the viscosity and density of a liquid or slurry for Newtonian fluids and the shear impedance of the liquid for non-Newtonian f ...
Full textLink to itemCite
Journal ArticleAIP Conference Proceedings · April 9, 2005
The on-line measurement of the viscosity-density product is accomplished by analyzing the multiple reflections of an ultrasonic shear horizontal (SH) wave within a quartz wedge. Many echoes are observed as the ultrasound is reflected from the two sides (in ...
Full textCite
Journal ArticleProceedings of SPIE - The International Society for Optical Engineering · 2000
A laboratory system was developed that utilized an ultrasonic pulse-echo technique to detect very small cracks emanating from the thread root of a tensile-stressed fastener. Primary benefits were 1) the ability to inspect the fastener without its removal f ...
Cite
Journal ArticleMed Dosim
Previous work demonstrated improved dosimetry of single isocenter volumetric modulated arc therapy (VMAT) of multiple intracranial targets when they are located ≤ 4cm from isocenter because of narrower multileaf collimators (MLCs). In follow-up, we sought ...
Full textLink to itemCite
ConferenceMed Dosim
This study aimed to report hippocampal dose from single-fraction stereotactic radiosurgery (SRS) for 4 to 10 brain metastases and determine feasibility of hippocampal-sparing SRS. Patients with 4 to 10 brain metastases receiving single-isocenter, multi-tar ...
Full textLink to itemCite
Journal ArticleMed Dosim
Linac based radiosurgery to multiple metastases is commonly planned with volumetric modulated arc therapy (VMAT) as it effectively achieves high conformality to complex target arrangements. However, as the number of targets increases, VMAT can struggle to ...
Full textLink to itemCite